Impact of cleaning brush and biopsy forceps on the surface roughness and bacterial adhesion of forceps channel in simulation
Author:
Affiliation:

The First Affiliated Hospital of Nanchang University, Nanchang 330006, China

Clc Number:

+2]]>

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Comments
    Abstract:

    Objective To analyze the effect of two instruments on the surface roughness (Ra) and bacterial adhesion of endoscope forceps channel. Methods Equal length sections of new polytetrafluoroethylene (Teflon) tubes were bent and fixed. Cleaning brush (Group A) and biopsy forceps (Group B) were used to simulate clinical operations with different passing frequencies. Surface roughness (Ra) and morphology were measured. Pseudomonas aeruginosa was inoculated onto the Teflon tubes in each group to evaluate surface colony-forming units and bacterial adhesion. Results Teflon tube surfaces without instrument passage were smooth and without scratches. As the passage frequency increased, surface scratches became denser, with more significant effects observed in Group A. At passage frequencies of 0, 50, 100, and 200, there were no statistically significant differences in Ra between Groups A and B. However, at a passage frequency of 500, Ra in Group A was greater than in Group B (P < 0.01). When comparing different passage frequencies within each group, there were no statistically significant differences between 0 and 50 passages, but Ra at 0 passages was significantly lower than at 100, 200, and 500 passages (P < 0.01). Initially, biofilms were evenly distributed on the Teflon tube surfaces without instrument passage, but with increased passage frequency, Group A showed more densely covered biofilms, with visible bacterial colonies at the scratch sites. There were no significant differences in colony counts between Groups A and B at 0, 50, 100, and 200 passage frequencies. However, at 500 passages, Group A had a higher colony count than Group B (P < 0.01). When comparing the colony counts at 50, 100, and 200 passage frequencies with those at 0 passages within each group, no statistically significant differences were found (P> 0.05). However, at 500 passages, the mean colony count in Group A was higher than at 0 passages (P < 0.01), while no statistically significant difference was observed in Group B compared to 0 passages (P=0.186). Conclusion Repeated passage of endoscope cleaning brush and biopsy forceps through forceps' channels increases the Ra of the endoscope forceps' channels, leading to an increase in bacterial adhesion. The effect is more significant with the cleaning brush. This highlights the need to strengthen the management of instrument usage in clinical settings and develop better cleaning tools.

    Reference
    Related
Get Citation

毕正琴,张洋洋,黄子怡,等.清洗刷与活检钳模拟通过内镜钳子管道对其表面粗糙度及细菌黏附性的影响[J].中国感染控制杂志英文版,2023,(8):919-924. DOI:10.12138/j. issn.1671-9638.20234008.
Zheng-qin BI, Yang-yang ZHANG, Zi-yi HUANG, et al. Impact of cleaning brush and biopsy forceps on the surface roughness and bacterial adhesion of forceps channel in simulation[J]. Chin J Infect Control, 2023,(8):919-924. DOI:10.12138/j. issn.1671-9638.20234008.

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:January 06,2023
  • Revised:
  • Adopted:
  • Online: April 28,2024
  • Published: