Survey on air purification methods applied in different types of hospitals
Author:
Affiliation:

1.Department of Healthcare-associated Infection Management-Disease Prevention and Control, Peking University First Hospital, Beijing 100034, China;2.Department of Infection Management, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310009, China;3.Department of Laboratory Medicine, Guangdong Provincial People's Hospital, Guangzhou 510008, China;4.Heilongjiang Province Center for Disease Control and Prevention, Harbin 150030, China;5.Department of Infection Management, People's Hospital of Xinjiang Uygur Atonomous Region, Urumqi 830001, China;6.Department of Infection Management, West China Hospital, Sichuan University, Chengdu 610041, China;7.Department of Healthcare-associated Infection Control, Xiangya Hospital, Central South University, Changsha 410008, China;8.Department of Infection Management, the Fourth Hospital of Hebei Medical University, Shijiazhuang 050019, China

Clc Number:

+2]]>

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Comments
    Abstract:

    Objective To understand the application of air purification methods in different hospitals. Methods A survey was conducted in hospitals of different levels and types in 7 provinces from 7 regions of China, to investigate the current application status of air purification methods in hospitals after the promulgation of Hospital Air Purification Management Code, including the application of different air purification methods, the combination of air purification methods, and the application of air purification methods in different regions. Results A total of 340 hospitals were surveyed. 38.53% (n=131) of which had negative pressure isolation wards, 81.47% (n=277) had clean operating rooms with cleaning technology, 97.35% (n=331) had air disinfectors. 70.00% (n=238) had two or more air purification methods simultaneously in a certain region. General intensive care unit, infectious disease department and fever clinic adopted three or more air purification methods, accounting for 55.93%, 43.01% and 38.49%, respectively. The most common combination was natural/mechanical ventilation+air disinfectors (83.19%, 198/238). 20.59% (49/238) used ultraviolet lamps additionally for the disinfection in rooms with clean technology. Except for non-clean operating rooms, delivery rooms, catheter rooms and disinfection supply center, over 80% areas had ventilation systems. Conclusion The selection of air purification methods is diverse, and the architectural design pays more attention to ventilation, but the selection of air purification methods is still excessive and non-standardized.

    Reference
    Related
Get Citation

贾会学,姚希,陆群,等.不同类型医院空气净化方式应用情况调查[J].中国感染控制杂志英文版,2023,(5):504-511. DOI:10.12138/j. issn.1671-9638.20233311.
Hui-xue JIA, Xi YAO, Qun LU, et al. Survey on air purification methods applied in different types of hospitals[J]. Chin J Infect Control, 2023,(5):504-511. DOI:10.12138/j. issn.1671-9638.20233311.

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:September 01,2022
  • Revised:
  • Adopted:
  • Online: April 28,2024
  • Published: