Dynamic disinfection effect of 222 nm upper-room ultraviolet irradiation on the air in bronchoscopy room of a tertiary first-class infectious disease hospital
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Comments
    Abstract:

    Objective To compare the dynamic disinfection effect of upper-room ultraviolet irradiation at 222 nm and 254 nm on the air in different areas of the bronchoscopy room of a tertiary first-class infectious disease hospital, and provide new insights for air disinfection in specialized diagnosis and treatment areas of medical institutions. Methods The treatment room and cleaning room of the bronchoscopy room of a tertiary first-class infectious disease hospital were selected. The upper-room ultraviolet irradiation air disinfectors of 254 nm (as control group) and 222 nm (as test group) were installed at a height of 2.6 meters above the ground in the first and the second working weeks, respectively. Difference in total bacterial colonies in the air between two groups was compared. Results The average bacterial colonies in the air of cleaning room and treatment room of bronchoscopy room in the test group were both lower than those of the control group (both P<0.05), and maintained a low level throughout the entire period. The qualified rates of dynamic air bacterial colonies in both the control group and the test group were 100%. The time percentage that the control group met the class I environmental level was 87.5%, while that of the test group was 100%. Conclusion The upper-room ultraviolet irradiation at 222 nm is more effective in improving the qualified rate of dynamic air bacterial colonies and enhancing the environment of the bronchoscopy room compared with upper-room ultraviolet irradiation at 254 nm, and continuous irradiation helps to maintain air safety and cleanliness.

    Reference
    Related
Get Citation

龚嫒媛,张芸,沈兴华,等.222 nm紫外线上层平射对某三级甲等传染病医院气管镜室空气动态消毒效果评价[J].中国感染控制杂志,2026,25(6):854-859. DOI:10.12138/j. issn.1671-9638.20263001.
GONG Aiyuan, ZHANG Yun, SHEN Xinghua, et al. Dynamic disinfection effect of 222 nm upper-room ultraviolet irradiation on the air in bronchoscopy room of a tertiary first-class infectious disease hospital[J]. Chin J Infect Control, 2026,25(6):854-859. DOI:10.12138/j. issn.1671-9638.20263001.

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:September 23,2025
  • Revised:
  • Adopted:
  • Online: June 27,2026
  • Published: June 28,2026