维持性血液透析导管相关感染风险预测模型构建与验证:一项回顾性队列研究
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

R197.32

基金项目:

“感·动中国”医疗机构感染预防与控制科研项目(GY2023023-A)


Development and validation of a risk prediction model for catheter-related infections in maintenance hemodialysis: a retrospective cohort study
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 文章评论
    摘要:

    目的 分析血液透析导管相关感染危险因素,构建风险预测模型,实现对血液透析导管相关感染高风险患者的早期识别。方法 回顾性分析2020年1月—2024年6月徐州医科大学附属医院330例维持性血液透析(MHD)患者,以确定导管相关感染危险因素,构建预测模型并进行内部验证,同时选取2022年1月—2024年6月武汉大学中南医院及青海省人民医院MHD置管患者进行外部验证。以受试者工作特征曲线下面积和Hosmer-Lemeshow拟合优度检验评价模型区分度和校准度,以决策曲线评价模型实用性,并绘制列线图模型。结果 研究显示,导管感染史(OR=2.837,P=0.022)、非首次置管(OR=3.682,P=0.001)、置管部位(股静脉)(OR=3.124,P=0.015)、置管时间长(OR=1.012,P=0.006)、糖尿病(OR=3.397,P<0.001)为MHD患者血液透析导管相关感染独立危险因素,清蛋白升高(OR=0.903,P=0.001)为保护因素。该模型在训练组、内部验证组及外部验证组均具有良好的区分度和校准度。结论 本研究构建的血液透析导管相关感染风险预测模型具有良好的预测效能,可作为临床筛查血液透析导管相关感染患者的风险评估工具,为血液透析导管相关感染防控提供参考。

    Abstract:

    Objective To identify risk factors for hemodialysis catheter-related infections through retrospective analysis and construct a risk prediction model to enable early identification of patients at high risk for such infections. Methods A retrospective analysis was conducted on 330 maintenance hemodialysis (MHD) patients at the Affiliated Hospital of Xuzhou Medical University from January 2020 to June 2024 to identify risk factors for catheter-related infections. A predictive model was constructed, and internal validation was performed. Patients receiving MHD catheterization from January 2022 to June 2024 at Zhongnan Hospital of Wuhan University and Qinghai Provincial People's Hospital were selected for external validation. The discriminative ability and calibration of the model were assessed using the area under the receiver operating characteristic curve and the Hosmer-Lemeshow goodness-of-fit test, respectively. Clinical utility was evaluated by decision curve analysis, and a nomogram model was developed. Results This study revealed that history of previous catheter infections (OR=2.837, P=0.022), non-first catheterization (OR=3.682, P=0.001), catheterization site (femoral vein) (OR=3.124, P=0.015), catheterization duration (OR=1.012, P=0.006), and diabetes (OR=3.397, P<0.001) were independent risk factors for catheter-related infections in MHD patients, while albumin (OR=0.903, P=0.001) served as a protective factor. The model demonstrated good discriminative ability and calibration across the training set, the internal validation set, and the external validation set. Conclusion The nomogram prediction model has good predictive performance, which can be used as a risk assessment tool for clinical screening of patients with catheter-related infections, and provides a reference for the prevention and control of hemodialysis (CRI).

    参考文献
    相似文献
引用本文

郭紫晴,云震,张冰,等.维持性血液透析导管相关感染风险预测模型构建与验证:一项回顾性队列研究[J]. 中国感染控制杂志,2026,25(8):1138-1147. DOI:10.12138/j. issn.1671-9638.20263287.
GUO Ziqing, YUN Zhen, ZHANG Bing, et al. Development and validation of a risk prediction model for catheter-related infections in maintenance hemodialysis: a retrospective cohort study[J]. Chin J Infect Control, 2026,25(8):1138-1147. DOI:10.12138/j. issn.1671-9638.20263287.

复制
分享
文章指标
  • 摘要阅读次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2025-12-04
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2026-08-27
  • 出版日期: 2026-08-28